[Jan-2022] Use Real NCS-Core Dumps - 100% Free NCS-Core Exam Dumps
NCS-Core PDF Dumps Exam Questions – Valid NCS-Core Dumps
NEW QUESTION 76
After installation, network ports are properly configured with the default active-backup bonding.
One 10GbE port goes to switch 1. Another 10GbE port goes to switch 2. A consultant tests failover by manually pulling one of the cables and notices it is taking too much time to failover, which is causing excessive packet loss.
What should the consultant enable to resolve this issue?
- A. PAgP
- B. LACP on switch
- C. Jumbo frames
- D. Portfast
Answer: D
NEW QUESTION 77
An administrator has a 32-node hybrid cluster with CPU, RAM and storage utilization of 80%. A database VM is configured with VM Flash.
What is causing this IO latency?
- A. Database VM is experiencing high CPU ready time.
- B. VM Flash Mode reduces SSD tier capacity for VMs.
- C. Curator scans causes by ILM constantly moving data.
- D. Controller VM is experiencing high CPU ready time.
Answer: D
NEW QUESTION 78
Refer to the exhibit.
An administrator is commissioning a Nutanix Enterprise Cloud. Once the user VMs have been deployed and are running, the administrator finds that VMs on the same host are able to communicate, but are unable to communicate between hosts.
What must be changed to enable full inter-VM communications?
- A. The VMs need to have static IPaddresses
- B. Change the network the VMs are connected to
- C. Update the switch to specifically allow VLAN 15
- D. Change the spanning-tree port type on the switch
Answer: C
Explanation:
Explanation
Ref:https://hyperhci.com/2019/11/09/nutanix-ahv-enable-vlan-trunk-mode-on-guest-vm/
NEW QUESTION 79
After a consultant runs Foundation, the imaging process fails.
In which two locations can the consultant find the logs? (Choose two.)
- A. On the CVM - /home/Nutanix/foundation/logs
- B. On the Foundation VM - /home/nutanix/foundation/logs
- C. Logs link on the Foundation Imaging Screen
- D. On the Hypervisor - /home/nutanix/foundation/logs
Answer: B,C
NEW QUESTION 80
A consultant is running the Foundation VM using desktop virtualization software. No nodes are discovered.
What should the consultant verify first?
- A. Host-only Adapter
- B. NAT
- C. Internal Network
- D. Bridged Adapter
Answer: D
NEW QUESTION 81
A customer needs a DR solution designed around the following requirements:
* There are 8 ms of latency between Sites A and B
* The administrator needs the shortest RPO/RTO possible
* Application consistent snapshots are required
* Use of NutanixVSS
Which Data Protection Method should be used?
- A. Cloud Connect
- B. Async
- C. Near Sync
- D. Metro Availability
Answer: C
Explanation:
Explanation
Ref:https://portal.nutanix.com/page/documents/details?targetId=Prism-Element-Data-Protection-Guide-v5_18:w
NEW QUESTION 82
A consultant creates an AHV cluster and connects the Intel X550T NICs to the top of rack switch using Twinax cables. The activity and link lights are green. The cluster cannot communicate over the 10GbE link.
What is the first command the consultant should perform to troubleshoot the issue?
- A. manage_ovs show_bridges
- B. manage_ovs show_interfaces
- C. manage_ovs show_uplinks
- D. manage_ovs update_uplinks
Answer: A
NEW QUESTION 83
A CEO asks the IT administrator to provide a list of required resources to protect current workloads and the two new SQL servers from a disaster. The Nutanix environment is managed by Prism Central.
Which option explains how to meet the CEO's request?
- A. Create a new Recovery policy by selecting the VM that needs to be protected and get hardwarerequirements.
- B. In Capacity Runway, select Optimize Resources and select all VMs that must be protected.
- C. Create a new scenario based on a new cluster based on a VM Profile and select Recommend.
- D. Create a new project and assign theVMs to it to get compute and storage requirements.
Answer: A
NEW QUESTION 84
A customer has a four-node cluster and is using Volume Groups toprovide storage services to a SQL cluster.
In the event of a CVM failure in the cluster, what is the expected IO path of the volume group's iSCSI targets?
- A. vDisk directed to CVM that failed to disconnect and will not reconnect without manual intervention
- B. vDisk directed at failed CVM will disconnect and reconnect when thefailed CVM comes back online
- C. vDisk directed to failed CVM are redirected to another CVM and automatically reconnect
- D. vDisk directed at failure CVM are redirected to Data Services IP until CVM is reconnected
Answer: C
NEW QUESTION 85
Microsegmentation was recently enabled in a Nutanix environment. The administrator wants to leverage Prism Central to create a policy that will block all traffic, regardless of direction, between two groups of VMs identified by their category.
Which policy should be used to meet this requirement?
- A. An Application Security Policy
- B. A Whitehst-Based Policy
- C. AnIsolation Environment Policy
- D. A Quarantine Policy
Answer: C
Explanation:
NEW QUESTION 86
An administrator needs to create and start five new VMs for a Data Analytics Project (OLAP). The VM Profile is as follows:
* vCPU:4
* vRAM: 64 GB
* vDisk: 1.5 TB
Each of the four nodes of the Nutanix cluster has the following:
* 24 vCPU. 20% overall usage
* 192 GB RAM, 60% overall usage
* 2xl920GBSSD
* 4x 2 TB HDD
At cluster level, there is a single RF2 container that is 30% utilized and has an extent store capacity of 13.5 TB.
Which component requires administrator attention?
- A. Physical Cores, because they are not enough to power on all of the new VMs.
- B. Flash Tier because it is not enough to accommodate the workloads.
- C. Physical RAM, because it is not enough to power on all of the new VMs.
- D. Storage, because the capacity is not enough to create VMs.
Answer: C
NEW QUESTION 87
A VM does not have enough resources for the demand,which leads to performance bottlenecks. The VM is exhibiting one or more of following baseline values, based on the past 30 days:
* CPU usage > 90% (moderate), 95% (high)
* CPU ready time > 5%, 10%
* Memory usage > 90%, 95%
* Memory swap rate > 0Kbps (no moderate value)
Which type of VM is being described?
- A. Bully VM
- B. Inactive VM
- C. Over-provisioned VM
- D. Constrained VM
Answer: D
Explanation:
NEW QUESTION 88
A Nutanix cluster has 10TB usable storage. The customer wants to create a 100GB datastore for ISO images to eliminate too much storage being consumed by unnecessary images.
Which setting should be used to accomplish this goal?
- A. From Container Advanced Settings, turn on compression and deduplication.
- B. From Container Advanced Settings, enable erasure coding.
- C. From Container Advanced Settings, configure 100GB for advertised capacity.
- D. From Container Advanced Settings, configure 100GB for reserved capacity.
Answer: C
NEW QUESTION 89
Where in the Support Portal is the Best Practices guide for vSphere Networking located?
- A. Knowledge Base
- B. Product Notices
- C. Software Documentation
- D. Solutions Documentation
Answer: D
NEW QUESTION 90
A customer has Metro Availability configured in Automatic Resume Mode between Site A and Site B What happens to VMs if Primary Site A has full network failure?
- A. Automatic protection domain promotion in Site B. VMs automatically restart in Site B
- B. VMs continue to run on Site A following an automatic disable of protection domains.
- C. An administrator must promote protection domains in Site B for VMs to restart.
- D. An administrator must unwitness in Site B and promote protectiondomains in Site B for VMs to restart
Answer: A
Explanation:
Explanation
Ref: https://support-portal.nutanix.com/page/documents/details/?targetId=Web-Console-Guide-Prism-v55:sto-me
NEW QUESTION 91
To prepare for a new Nutanix installation, a consultant downloads the Foundation VM, imports the VM to their Desktop Virtualization Solution, and powers on the VM. The IPv4 static address on the host workstation and the Foundation VM have been configured, but pings between them fail.
Which two troubleshooting steps should the consultant perform? (Choose two.)
- A. Verify the virtual NIC in the Foundation VM is bound to the correct wireless network adapter.
- B. Remove and re-import the Foundation VM to ensure the virtual NIC is set to Host-Only.
- C. Confirm the IP addresses and subnet masks are correct.
- D. Verify the virtual NIC in the Foundation VM is bound to the correct physical Host adapter.
Answer: C,D
NEW QUESTION 92
......
Ultimate NCS-Core Guide to Prepare Free Latest Nutanix Practice Tests Dumps: https://www.actualpdf.com/NCS-Core_exam-dumps.html
Get Top-Rated Nutanix NCS-Core Exam Dumps Now: https://drive.google.com/open?id=1WqVnVQu5gfMt_mHNIDV7TAnjQBywJzkH
