NEW QUESTION # 30
Exhibit.
A Linux host with the 10.0.1.24 IP address is unable to mount the VOL_A volume using NFSv3.
Referring to the exhibit, what is the problem?
- A. The host IP address does not match the export policy rule.
- B. The volume is in read-only.
- C. The logical Interface does not allow the NFSv3 protocol.
- D. The volume is not mounted In the namespace.
Answer: A
NEW QUESTION # 31
Which two components are required for committing data to a WORM volume? (Choose two.)
- A. You must create a SnapLock volume.
- B. You must create a SnapLock SVM.
- C. You must create a SnapLock Aggregate.
- D. You must license SnapLock.
Answer: A,D
NEW QUESTION # 32
Your company has purchased two NetApp AFF A400 HA pairs. During deployment, how many root aggregates are created?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION # 33
When you set up an ONTAP cluster, which two SVM types are automatically created? (Choose two.)
- A. node
- B. data
- C. cluster
- D. admin
Answer: A,B
NEW QUESTION # 34
Exhibit.
A Linux host with the 10.0.1.24 IP address is unable to mount the VOL_A volume using NFSv3.
Referring to the exhibit, what is the problem?
- A. The host IP address does not match the export policy rule.
- B. The volume is in read-only.
- C. The logical Interface does not allow the NFSv3 protocol.
- D. The volume is not mounted In the namespace.
Answer: D
Explanation:
The volume is not mounted in the namespace. https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.cdot-famg-nfs%2FGUID-8E400D78-B405-4682-8F33-143783F2D580.html Even if the volume was read only it could be mounted - also the client IP is in the desired range and LIF is configured for NFS.
NEW QUESTION # 35
You want to prepare your ONTAP cluster and your ESXI cluster to connect NFS datastores over a 10-GbE network using Jumbo frames. In this scenario, which three configurations would accomplish this task?
(Choose three.)
- A. Enable Jumbo frames with an MTU of 1500 for your ESXI hosts.
- B. Enable Jumbo frames with an MTU of 9000 for your ONTAP cluster.
- C. Enable Jumbo frames with an MTU of 1500 for your ONTAP cluster.
- D. Enable jumbo frames with an MTU of 9000 for your ESXi hosts.
- E. Enable jumbo frames with an MTU of 9216 for your switches.
Answer: B,D,E
NEW QUESTION # 36
Exhibit.
You have a 2-node NetApp FAS2750 ONTAP cluster. You create a new 20-GB LUN In a new 100-GB volume and write 10 GB of data to the LUN. No storage efficiencies are enabled for the volume or aggregate.
Referring to the exhibit, which two statements are true? (Choose two.)
- A. ONTAP reports the volume as 20% full.
- B. ONTAP reports the volume as 10% full.
- C. ONTAP reports that the volume Is using 10 GB of Its containing aggregate.
- D. ONTAP reports that the volume Is using 100 GB of its containing aggregate.
Answer: B,C
NEW QUESTION # 37
You are asked to create a new SVM to serve SMB data using Active Directory authentication.
Which two requirements must be satisfied prior to serving data? (Choose two.)
- A. DNS must be enabled and configured correctly.
- B. An administrative user must be created for the SMB SVM.
- C. An intercluster LIF must be created for serving SMB data.
- D. The CIFS license must be installed on the storage system.
Answer: A,D
NEW QUESTION # 38
Your company runs a NetApp AFF A220 cluster as a file server for NFS and SMB. You want to use one of the unused ports to connect a single Windows host directly, using FC. You have converted the UTA2 ports e0e and e0f to FC and equipped them with a 16-Gbps FC transceiver. Your Windows host fails to connect to the storage.
In this scenario, which action solves the problem?
- A. Use an FC switch between storage and host.
- B. Use the arbitrated loop topology on storage and host.
- C. Use an Ethernet switch between storage and host.
- D. Use the point-to-point topology on all ports.
Answer: D
Explanation:
Explanation
The point-to-point topology is the simplest and most common way to connect a single host to a storage system using FC. It allows direct communication between two devices without any intermediate devices. The UTA2 ports on the AFF A220 cluster support the point-to-point topology when configured as FC ports. Therefore, to connect a single Windows host directly to the storage using FC, you need to use the point-to-point topology on all ports and make sure that the host and the storage have compatible FC settings, such as speed, WWPN, and zoning. The other options are not correct because they involve additional devices or topologies that are not necessary or supported for this scenario. References :- Quick guide - AFF A220, Detailed guide - AFF A220, ONTAP 9 SAN Configuration Guide
NEW QUESTION # 39
Due to the increasing threat of ransomware, you must implement a secure and fast solution to recover files in your ONTAP cluster. The users should be able to recover their files from their Windows Desktop.
In this scenario, which two steps fulfill this requirement? (Choose two.)
- A. Ensure that the option to copy a FlexClone of each volume containing files is activated.
- B. Ensure that the option to show previous versions on the SVM Is activated.
- C. Ensure that there is a Snapshot copy schedule for every volume containing files.
- D. Ensure that the option to show previous versions on each share is activated.
Answer: B,D
NEW QUESTION # 40
You are planning an installation of a new stack of shelves to an HA pair and need to locate empty SAS ports...
In this scenario, which tool would you use to accomplish this task remotely?
- A. Interoperability Matrix Tool
- B. Hardware Universe
- C. ONTAP System Manager
- D. Active IQ Web site
Answer: A
NEW QUESTION # 41
Exhibit.
You have received an alert from Active IQ Unified Manager that interface eOc has gone offline. Network engineering asks for the corresponding MAC address for the port that has a problem.
Referring to the exhibit, which MAC address would you supply to the engineering team?
- A. 02:a0:98:fl:2e:be
- B. 02:a0:98:fl:21:88
- C. 00:a0:98:fl:2e:b3
- D. 00:a0:98:fl:2e:b2
Answer: C
NEW QUESTION # 42
Exhibit.
You have a 2-node NetApp FAS2750 ONTAP cluster. You create a new 20-GB LUN In a new 100-GB volume and write 10 GB of data to the LUN. No storage efficiencies are enabled for the volume or aggregate.
Referring to the exhibit, which two statements are true? (Choose two.)
- A. ONTAP reports the volume as 10% full.
- B. ONTAP reports that the volume Is using 10 GB of Its containing aggregate.
- C. ONTAP reports the volume as 20% full.
- D. ONTAP reports that the volume Is using 100 GB of its containing aggregate.
Answer: C,D
NEW QUESTION # 43
Which two storage efficiencies are enabled by default on NetApp AFF systems? (Choose two.)
- A. postprocess compaction
- B. Inline compression
- C. postprocess zero block detection
- D. Inline deduplication
Answer: C,D
NEW QUESTION # 44
A user wants existing data in a FlexVol created in ONTAP 9.1 to be placed into a FlexGroup volume with ONTAP 9.8. In this scenario, which two statements are true? (Choose two.)
- A. You can convert the FlexVol volume to a FlexGroup volume.
- B. Use SnapMirror to replicate data from FlexVol to FlexGroup.
- C. Use XCP to copy data from a FlexVol to a FlexGroup.
- D. A FlexVol to FlexGroup conversion is not supported.
Answer: C,D
NEW QUESTION # 45
Which configuration Is supported using NetApp's All SAN Array (ASA)?
- A. 24-node cluster
- B. single node cluster
- C. 12-node cluster
- D. 2-node cluster
Answer: A
NEW QUESTION # 46
A user wants existing data in a FlexVol created in ONTAP 9.1 to be placed into a FlexGroup volume with ONTAP 9.8. In this scenario, which two statements are true? (Choose two.)
- A. Use SnapMirror to replicate data from FlexVol to FlexGroup.
- B. Use XCP to copy data from a FlexVol to a FlexGroup.
- C. A FlexVol to FlexGroup conversion is not supported.
- D. You can convert the FlexVol volume to a FlexGroup volume.
Answer: B,D
Explanation:
Explanation
You can use either XCP or the in-place conversion feature to move data from a FlexVol volume to a FlexGroup volume. XCP is a data migration tool that can copy data between different types of volumes, such as FlexVol and FlexGroup. The in-place conversion feature, introduced in ONTAP 9.7, allows you to convert a FlexVol volume to a FlexGroup volume without requiring a data copy or additional disk space. However, you cannot convert a FlexGroup volume back to a FlexVol volume. SnapMirror is not a valid option for this scenario, because it does not support replicating data from FlexVol to FlexGroup volumes. A FlexVol to FlexGroup conversion is supported, but only for transitioned volumes starting from ONTAP 9.8. References
:- Converting FlexVol volumes to FlexGroup volumes overview, Can a FlexGroup be converted to a FlexVol?, Can I convert a Flexvol to FlexGroup without rewarming the tiered data?
NEW QUESTION # 47
You currently have a Cloud Volumes ONTAP instance running and need to have read/write access to a volume on an on-premises ONTAP cluster.
In this scenario, which feature do you use?
- A. Flash Pool
- B. Flash Cache
- C. SnapMirror
- D. FlexCache
Answer: C
NEW QUESTION # 48
You have a 50 TO FlexGroup volume that is serving NFSv3 on a FAS8300 HA pair that Is running ONTAP 9.8 software of files. A Linux du command runs for days to count files.
In this scenario, which native ONTAP feature will report real-time file counts?
- A. volume autosize
- B. File System Analytics
- C. Quality of Service
- D. Logical Space Reporting
Answer: B
NEW QUESTION # 49
You have finished deploying a NetApp AFF A400 cluster.
Before you place the array into production, which two tools should be used to validate the deployment?
(Choose two.)
- A. Active IQ Unified Manager
- B. Active IQ Web site
- C. OnCommand Workflow Automation
- D. Active IQ Config Advisor
Answer: A,D
Explanation:
Explanation
Active IQ Unified Manager is a web-based tool that monitors the health, performance, capacity, and protection of clusters and SVMs. It provides alerts, reports, dashboards, and recommendations to help optimize and troubleshoot the ONTAP environment. Active IQ Unified Manager can be used to validate the deployment of a NetApp AFF A400 cluster by checking the cluster configuration, status, and efficiency1.
Active IQ Config Advisor is a desktop tool that scans the cluster and its components for configuration issues, best practices violations, and potential problems. It generates a report that identifies the errors, warnings, and informational messages along with the suggested actions to resolve them. Active IQ Config Advisor can be used to validate the deployment of a NetApp AFF A400 cluster by verifying the hardware, software, network, and storage settings2.
The other tools are not relevant for validating the deployment of a NetApp AFF A400 cluster. OnCommand Workflow Automation is a tool that automates storage management tasks using predefined or custom workflows. Active IQ Web site is a tool that provides insights and recommendations based on the data collected from NetApp systems34. References :- Active IQ Unified Manager overview, Active IQ Config Advisor overview, OnCommand Workflow Automation overview, Active IQ overview
NEW QUESTION # 50
Your company requires WORM archiving of data on their ONTAP cluster. The data must not be able to be deleted even by an administrator. Which ONTAP feature fulfills this requirement?
- A. SnapLock Enterprise
- B. SnapVault software
- C. SnapMlrror software
- D. SnapLock Compliance
Answer: D
NEW QUESTION # 51
You want to scale out storage performance for read-Intensive data across multiple locations. In this scenario, which NetApp feature accomplishes this task?
- A. FlexClone
- B. Flash Pool
- C. FlexVol
- D. FlexCache
Answer: A
NEW QUESTION # 52
You are an administrator that manages a number of mission-critical applications that use block protocols only. The business unit requires the fastest storage failover.
In this scenario, which ONTAP solution satisfies the requirement?
- A. ONTAP Select with Asymmetric Logical Unit Access (ALUA)
- B. All SAN Array (ASA) with symmetric active-active topology
- C. FAS with symmetric active-active topology
- D. AFF with Asymmetric Logical Unit Access (ALUA)
Answer: B
NEW QUESTION # 53
You currently have an 8-node cluster and want to perform a rolling upgrade to a newer version of ONTAD to solve security issues reported in the Active IQ Web site.
In this scenario, which two steps should you validate before you perform the upgrade? (Choose two.)
- A. Run Active 1Q Config Advisor.
- B. Run Upgrade Advisor Report.
- C. Validate Nodes with Hardware Universe.
- D. Validate Nodes with Active IQ Unified Manager.
Answer: A,B
NEW QUESTION # 54
Click the Exhibit button.
You have an AFF A400 HA pair serving SMB locally and a FAS8300 HA pair serving SMB over FlexCache Both clusters are running ONTAP 9.8 software.
In this scenario, which two protocol features are supported at the remote cache? (Choose two.)
- A. SMB3 continuously available (CA) shares
- B. file locking
- C. multiprotocol NFSv4.1
- D. multiprotocol NFSv3
Answer: A,C
NEW QUESTION # 55
......