EMC E20-260 Exam Overview:
| Certification Vendor: | Dell EMC |
|---|---|
| Exam Name: | VPLEX Specialist Exam for Implementation Engineers |
| Exam Number: | E20-260 |
| Exam Format: | Scenario-based, Multiple choice |
| Certificate Validity Period: | 3 years |
| Available Languages: | English |
| Exam Price: | $230 USD |
| Exam Duration: | 90 minutes |
| Real Exam Qty: | 60 |
| Related Certifications: | Associate - Information Storage and Management (all versions) |
| Passing Score: | 63% |
| Recommended Training: | Dell EMC VPLEX Implementation and Management Training |
| Exam Registration: | Dell Technologies Proven Professional Pearson VUE Registration |
| Sample Questions: | ![]() |
| Exam Way: | Computer-based test, online proctored or onsite at Pearson VUE centers |
| Pre Condition: | Hold valid Associate - Information Storage and Management certification (Version 1.0, 2.0, 3.0, 4.0 or 5.0) |
| Official Syllabus URL: | https://learning.dell.com/content/dam/dell-emc/documents/en-us/E20_260_IE_VPLEX_Specialist_Exam.pdf |
EMC E20-260 Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| VPLEX Storage Provisioning | 20% | - Host connectivity and access - Back-end storage integration - Virtual volumes and storage views - Storage pools and extent creation |
| Upgrades and Troubleshooting | 13% | - Support tools and data collection - Software and firmware upgrades - Common operational issues - Troubleshooting methodology |
| VPLEX Monitoring and Reporting | 10% | - Event logging and alerts - Reporting and diagnostic tools - System health and performance monitoring |
| VPLEX Concepts and Architecture | 13% | - VPLEX Local and Metro configurations - VPLEX components and architecture - Virtualization and data mobility principles |
| VPLEX Installation and Setup | 23% | - Network and SAN zoning configuration - Site planning and preparation - Hardware installation and cabling - Software installation and initial configuration |
| Volume Management and Protection | 20% | - High availability and failover - Distributed devices and consistency groups - VPLEX mobility and migration - Integration with replication technologies |
Questions and Answers About EMC VPLEX Specialist Exam for Implementation Engineers
EMC VPLEX Specialist Exam for Implementation Engineers is an official Dell EMC exam, listed under exam code E20-260. A passing result earns you the Specialist - Implementation Engineer, VPLEX Version 2.0 certification at the Specialist level. It also ties into Associate - Information Storage and Management (all versions), extending its value across your certification roadmap. Employers read this credential as verified competence, which is why it keeps appearing in job requirements.
Expect 60 questions inside 90 minutes on the EMC VPLEX Specialist Exam for Implementation Engineers exam. That pace punishes hesitation, so rehearse it: the ActualPDF software engine simulates the real exam scene, reminds you of the questions you got wrong, and pushes you to re-practice them until the clock stops being your enemy.
Passing EMC VPLEX Specialist Exam for Implementation Engineers requires 63%, and the official registration fee is $230 USD. Retakes charge the full $230 USD again, which is why experienced candidates treat preparation as the cheaper exam fee. Verify your readiness with repeated ActualPDF practice scores above the requirement before you commit to a date.
Hold valid Associate - Information Storage and Management certification (Version 1.0, 2.0, 3.0, 4.0 or 5.0)
Requirements evolve, so confirm the current conditions before registering on the official exam page.
Registration for EMC VPLEX Specialist Exam for Implementation Engineers goes through the official channels listed here.
When you schedule, note that the exam is delivered Computer-based test, online proctored or onsite at Pearson VUE centers.
Dell EMC recommends the following training for EMC VPLEX Specialist Exam for Implementation Engineers candidates.
Follow any course with the 210 practice questions in the ActualPDF E20-260 package; the software engine will even remind you which mistakes need another round.
Yes. ActualPDF provides a free download demo of the EMC VPLEX Specialist Exam for Implementation Engineers material, so you can check the content before choosing a version. After purchase, a one-year warranty covers you: the latest version is sent to you as it releases, free for 365 days, and after expiry you can extend the update service at a 50% discount.
Your purchase is covered by a 100% money-back guarantee with clear conditions. Take the EMC VPLEX Specialist Exam for Implementation Engineers exam within 60 days of purchase; if you fail, provide your unqualified result by submitting a scanned enrollment slip and the official Score Report PDF within 2 days of the exam, and the full refund is processed within 7 days. The exam must match your product, candidate and payer names must match, and attempts within 3 days of purchase, unused downloads, free materials, and expired orders are not covered. Alternatively, exchange for two other exam products of equal value, free, or wait for updates while keeping your original product's update service.
Delivery is instant: files unlock for download at payment and are emailed within one minute. If nothing arrives within 2 hours, check spam and contact customer service, which works 7/24 and normally replies within two hours. Installation is unlimited across your computers.
The EMC VPLEX Specialist Exam for Implementation Engineers syllabus spans 6 domains, led by VPLEX Installation and Setup (23%), Upgrades and Troubleshooting (13%), and Volume Management and Protection (20%). The complete topic list is published above; candidates who study the map first rarely get lost later.
EMC VPLEX Specialist Exam for Implementation Engineers Sample Questions:
Refer to the exhibit.
After a power disruption of 20 seconds in a VPLEX environment, the output of the "vault status" command shows no vaulting processes.
Why did this occur?
- A. Cache vaulting process has already completed.
- B. It is the expected output, because the command "vault status" doesn't show information on cache process at all.
- C. Cache vaulting process is still running in background and it is not shown until completed.
- D. The cache vaulting did not exceed the timer period.
A VPLEX administrator claims a 100GB Storage Volume that is thin provisioned on the storage array and has 25GB physically allocated and creates a 1:1 encapsulated virtual volume. After a local data mobility job for that Virtual Volume, the storage array administrator notices that the allocated capacity has increased to 100GB. Why did this happen?
- A. Neither the source nor the destination Storage Volume were claimed with the thin-rebuild parameter in VPLEX.
- B. VPLEX does not support thin devices.
- C. The source Storage Volume was not claimed with the thin-rebuild parameter in VPLEX.
- D. The destination Storage Volume was not claimed with the thin-rebuild parameter in VPLEX.
Following EMC best practices, which information is required to register a VPLEX on an ESRS portal?
- A. Site ID; engine serial number; Management server eth3 IP address
- B. Site ID; cluster TLA serial number; Management server eth3 IP address
- C. License ID; engine serial number; Management server eth3 IP address
- D. Site ID; cluster TLA serial number; Witness IP address
Refer to the exhibit.
You are preparing to perform an upgrade on an unconfigured VPLEX Metro. When you run the ndu pre-check command, it indicates that it has failed and there are no first upgraders. In your troubleshooting, you run the version -a command.
Based on the output, what is the reason for the failure?
- A. Directors are at incompatible code levels
- B. Directors are not connected.
- C. ndu pre-check --force flag was not used
- D. health-check --full was not run
Which is the best way to identify the root cause of long read latencies using monitors?
- A. Check the difference between fe-director.read-lat and storage-volume.read-latency
- B. Check if the %CPU Busy is above 50%
- C. Check to see if all volumes are in at least 1 Consistency Group
- D. Check the ratio of cache.rhit to cache.miss